Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Journal of Experimental Ophthalmology ; (12): 1170-1175, 2022.
Article in Chinese | WPRIM | ID: wpr-990794

ABSTRACT

Objective:To compare the accuracy of IOLMaster 700 and IOLMaster 500 in intraocular lens (IOL) power calculation.Methods:A cross-sectional study was conducted.Two hundred and sixty-two eyes of 262 patients who underwent phacoemulsification combined with IOL implantation at the Eye Hospital of Wenzhou Medical University from November 2018 to November 2019 were enrolled.Preoperative biometry for cataract surgery was performed using IOLMaster 700 and IOLMaster 500.IOL power was calculated through the built-in formulas, Haigis, Holladay Ⅰ, Hoffer Q and SRK/T of the two devices.The difference in IOL power calculation between the two devices was analyzed through the prediction error of IOL power calculation using different formulas across different axial length (AL) ranges.This study complied with the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of the Eye Hospital of Wenzhou Medical University (No.2020-038-K-33). Written informed consent was obtained from each patient before the surgery.Results:There was no significant difference in mean absolute error (MAE) between IOLMaster 700 and IOLMaster 500 using Haigis, Hoffer Q and SRK/T over the entire AL range (all at P >0.05). The MAE of IOLMaster 500 was 0.47 (0.24, 0.90) D, which was significantly lower than 0.50 (0.28, 0.99) D of IOLMaster 700 using Holladay Ⅰ formula ( Z=-3.120, P=0.002). When AL was <22.0 mm and ≥24.5 mm-<26.0 mm, there was no significant difference in MAE between the two devices using the four formulas (all at P >0.05). When AL was ≥22.0 mm-24.5 mm, there was no significant difference in the MAE between the two devices using Haigis, Hoffer Q and SRK/T (all at P >0.05), but 0.42 (0.18, 0.75) D from IOLMaster 500 was smaller than 0.45 (0.25, 0.79) D from IOLMaster 700 using Holladay Ⅰ, showing a statistically significant difference ( Z=-3.487, P <0.001). But the difference was negligible and therefore was of no clinical significance.When AL was ≥26.0 mm, there was no statistically significant difference in the MAE between the two devices using Haigis, Holladay Ⅰ and SRK/T, but 0.66 (0.38, 1.00) D from IOLMaster 500 was significantly smaller than 0.98 (0.62, 1.32) D from IOLMaster 700 using Hoffer Q ( Z=-3.046, P=0.002). Conclusions:The refractive prediction accuracy of IOLMaster 700 and IOLMaster 500 using Haigis, Hoffer Q and SRK/T is similar over the entire AL range.For patient with long AL, the IOL calculation from IOLMaster 700 using Hoffer Q is significantly larger than that from IOLMaster 500, which requires extra caution in clinical practice.The accuracy of IOLMaster 700 and IOLMaster 500 for IOL prediction is very similar.

2.
Chinese Journal of Experimental Ophthalmology ; (12): 342-347, 2020.
Article in Chinese | WPRIM | ID: wpr-865273

ABSTRACT

Objective:To assess the applying value of Chinese shorter version of the Visual Function Index questionnaire (VF-11R-CN) for presenting low-vision cataract pre-operation and post-operation by using minimal clinically important difference (MCID) determined by combination of distribution-based with anchor-based methods, and to compare the improvement rate of vision-related quality of life (VRQol).Methods:A cross-sectional study was performed in this study.Ninety-eight patients with presenting low vision cataract were enrolled at Eye Hospital of Wenzhou Medical University from May 2018 to June 2019.All the patients received a phacoemulsification with intraocular lens implantation.A questionnaire survey was carried out with VF-11R-CN Scale before surgery and 1 month-3 months after surgery, and a complement anchor item was added during the questionnaire after surgery.The applicability of the scale was assessed by floor or ceiling effects, and score difference of the VF-11R-CN over time and effective size was determined.Distribution-based MCID was calculated using 0.5 standard deviation (SD) of score difference and 1.96 standard error of measurement (SEM). Anchor-based MCID was calculated using the slope of the linear regression analysis.In responder analysis, sensitivity and specificity of MCID was reported.The differences of postoperative VRQol improvement rate based-on MCID were compared between male and female, single eye disease and multiple eye diseases, pre-operative and post-operative scores.This study protocol was approved by the Ethics Committee of Eye Hospital of Wenzhou Medical University, and followed the Declaration of Helsinki.Written informed consent was obtained from each patient prior to any medical examination.Results:A total of 85 patients completed the following up.The mean score difference was 399.51±234.92, and that of the presenting visual acuity (PVA) was 0.65±0.36.Both the minor floor and ceiling effects were 1.18% before surgery, and the ceiling effects were 22.35% after surgery.The score before surgery was significantly higher than that after surgery ( t=15.68, P<0.001). The effective size for the surgery was 1.63.The MCID was 122.23 and 123.10 according to 0.5 SD and 1.96 SEM.The linearity regression analysis showed that score difference reduced 106.17 if anchor item option increased 1.The average MCID estimate was 117.17.A total of 76 patients (89.41%) reported an improvement of VRQol.The sensitivity of MCID for the assessment of VRQol was 96.67% and specificity was 46.67%.No significant differences were found in VRQol improvement rate between gender, single cataract and multiple eye diseases or PVA (LogMAR 1.3 as cutoff value) ( P=0.73, 0.88, 0.27). Conclusions:VF-11R-CN scale is available for Chinese presenting low vision cataract patients undergoing surgery.The MCID value for the cataract surgery is 117.17 scores, with a high sensitivity and a relatively low specificity.

3.
Chinese Journal of Experimental Ophthalmology ; (12): 357-362, 2016.
Article in Chinese | WPRIM | ID: wpr-637691

ABSTRACT

Background The assessment of total corneal power is essential to both the prediction of intraocular lens power before cataract surgery and the diagnosis of corneal ectasia.Objective This study was to access the repeatability of corneal power measurements in post-laser assisted in-situ keratomileusis (LASIK) eyes with GalileiⅡ dual Scheimpflug analyzer.Methods In this cross-sectional study,68 eyes of 36 subjects who received LASIK surgery more than 3 months in Eye Hospital of Wenzhou Medical University were recruited from July to September in 2011.The mean preoperative spherical equivalent diopter was (-4.95±2.08) D in the subjects with the diopter range from-1.75 D to-10.00 D.The parameters of corneal power were measured by Galilei Ⅱ dual Scheimpflug analyzer,including SimK,Ka,Kp,KG and Kray.Three-time consecutive measurements were completed in every examined eye to obtain the data of SimK,Ka,Kp,KG and Kray,respectively.The coefficient of variation (CV),standard deviation (SD),Cronbach α coefficient and intra-class correlation coefficient (ICC) were calculated to evaluate the repeatability.Concordance between the different measurements was assessed using Bland-Altman agreement analysis.This study followed the Helsinki Declaration,all subjects signed informed consent.Results The CVs of three-time measured SimK,Ka,Kp,KG and Kray were 0.24%,0.28%,-0.37%,0.31% and 0.32%,respectively,and the Cronbach α values were >0.9 and the ICCs were >0.982.The Bland-Altman analysis between different measurements showed that the maximum 95% limits of agreement (LoA) were 0.37 D for SimK,0.46 D for Ka,0.09 D for Kp,0.45 D for KG and 0.49 D for Kray,respectively.Conclusions The Galilei Ⅱ dual Scheimpflug analyzer performed high repeatability and concordance on corneal power measurements in post-LASIK eyes.The differences between measuring results are clinically acceptable.

4.
Chinese Journal of Biotechnology ; (12): 1520-1527, 2015.
Article in Chinese | WPRIM | ID: wpr-337469

ABSTRACT

1,3-propanediol is an important chemical used as building block for the synthesis of highly promising polyesters such as polytrimethylene terephthalate. A genetically modified Klebsiella pneumoniae LDH526 can use glycerol as sole carbon source and produce 1,3-propanediol with the titer above 90 g/L. A key factor affecting the production of 1,3-propanediol by the mutant K. pneumoniae is the accurate control of the feeding of glycerol. To generate a robust and reproducible fermentation process of 1,3-propanediol, we designed and optimized an automatically feeding strategy of glycerol based on fermentation kinetics. By coupling the substrate feeding rate with easily observed variables -pH and fermentation time, we have achieved self-starting glycerol feeding and dynamic control of the glycerol concentration during the fermentation process. This automated system allowed us to generate a reproducible, consistent and operator-independent process from lab-scale to production scale. The final concentration of 1,3-propanediol was above 95 g/L after 72 h.


Subject(s)
Culture Media , Fermentation , Glycerol , Industrial Microbiology , Methods , Klebsiella pneumoniae , Propylene Glycol , Propylene Glycols , Metabolism
5.
Chinese Journal of Microbiology and Immunology ; (12): 1094-1098, 2009.
Article in Chinese | WPRIM | ID: wpr-380287

ABSTRACT

Objective To clone the mature peptide gene of seo, construct two kinds of prokaryotic fusion expression vector, obtain recombinant staphylococcal enterotoxin O(SEO) and evaluate its biological activity. Methods The seo gene was amplified from ZNZ2-3 strain of Staphylococcus xylosus by designed primers and it was cloned into fusion vector pGEX-6P-1 and pET28a. The soluble recombinant protein(GST-SEO) was expressed in E. coli BL21 host cells, the purified GST-SEO was obtained by a single step of affini-ty chromatography using Glutathinione Sepharose 4B colume. Another fusion protein(P28-SEO) with his-tag was expressed in E. coli BL21 ( DE3), the purified P28-SEO protein was harvested by nickel chelate affinity chromatography method. The antigenicity of recombinant SEO was tested by Western blot. The stimulating effects of recombinant SEO on mouse lymphocytes was tested by MTT. The activity of Caspase 3 and the ap-optosis of DNA ladder were tested. Results The nucleotide sequence of the cloned seo gene was the same as that of reported in GenBank. The soluble recombinant protein GST-SEO was expressed at 25% expression level, and P28-SEO was 22%. The Western blot by GST-SEO-positive sera demonstrated that the recombi-nant SEO had good immunogenicity. The MTY assay of the enterotoxin activity showed that low dose of re-combinant SEO stimulated the proliferation of mice spleen lymphocytes, higher doses will lead to apoptosis. Conclusion Two of the recombinant SEO still have superantigen activity, and can lead to apoptosis of mice splenocytes.

SELECTION OF CITATIONS
SEARCH DETAIL